- Packet - Class in com.devmel.rf
-
- Packet(int, long, int) - Constructor for class com.devmel.rf.Packet
-
Constructs a Packet object.
- Packet(int, long, int, int) - Constructor for class com.devmel.rf.Packet
-
Constructs a Packet object.
- Packet(Packet) - Constructor for class com.devmel.rf.Packet
-
Constructs a Packet object as equal copy
- Protocol_AVD - Static variable in class com.devmel.rf.Packet
-
Protocol AVD
Avidsen
Value (4 bits) (0x0 = on ; 0x1 : off)
- Protocol_B12 - Static variable in class com.devmel.rf.Packet
-
Protocol Simple 12 bits
Monseigneur T1SAW433
- Protocol_B12_1 - Static variable in class com.devmel.rf.Packet
-
- Protocol_BLYP0 - Static variable in class com.devmel.rf.Packet
-
Protocol BLYP0
Blyss
Value (4 bits) (0x0 = on ; 0x1 : off)
- Protocol_DIO - Static variable in class com.devmel.rf.Packet
-
Protocol DIO
Chacon / DI-O / OTIO / CoCo Technologies / KlikAanKlikUit / Nexa
Value (2 bits) (1bit = all button channel ; 1bit = on/off)
- Protocol_DOOYA - Static variable in class com.devmel.rf.Packet
-
Protocol Dooya
DC305,DC306,DC307,DC313,DC1650,DC1651,DC2700
aluprof / yooda
Value (4 bits) (0x1 = up ; 0x3 : down ; stop : 0x5 ; prog : 0xc)
- Protocol_EQT - Static variable in class com.devmel.rf.Packet
-
Protocol Equation
Value (8 bits) (0x11 = on ; 0x01 = off)
- Protocol_EV1527 - Static variable in class com.devmel.rf.Packet
-
Protocol EV1527
Remote with button (A,B,C,D)
Value (4 bits) (0x2 : A ; 0x8 : B ; 0x1 : C ; 0x4 : D)
- Protocol_EV1527_1 - Static variable in class com.devmel.rf.Packet
-
- Protocol_EVF - Static variable in class com.devmel.rf.Packet
-
Protocol Everflourish
Value (4 bits) (0xf = on ; 0x00 = off)
- Protocol_FLOR - Static variable in class com.devmel.rf.Packet
-
Protocol Flor
Nice Flor 52 bits
NiceWay, WM001G, WM002G, WM003G, WM004G, WM006G et WM080G
Value (4 bits) (0x1 = up ; 0x4 : down ; stop : 0x2)
Need rolling code
- Protocol_GT7000 - Static variable in class com.devmel.rf.Packet
-
Protocol GT7000
Globaltronics GT-7000/GT-8000/GT-FSI, Conrad RC-710
Value (3 bits) (1bit = 1:all button channel ; 1bit = 1:on/0:off ; 1bit = 1:dimmer/0:switch)
- Protocol_HCTEL - Static variable in class com.devmel.rf.Packet
-
Protocol HCTEL
HomeConfort / SmartHome TEL-010
Value (8 bits) (0x81 = on ; 0x01 : off)
- Protocol_OTI - Static variable in class com.devmel.rf.Packet
-
Protocol OTI
OTIO 09HA02, 750060, 750061, 750062
Value (1 bits) (0x1 = on ; 0x0 : off)
- Protocol_PT2262 - Static variable in class com.devmel.rf.Packet
-
Protocol PrinceTon 2262
Most of DIP / rotary switch
Home Easy, Intertechno, Elro, HomeConfort YC
Value (2 bits) (0x2 = on ; 0x1 : off)
- Protocol_RFY - Static variable in class com.devmel.rf.Packet
-
Protocol Somfy
Simu / Somfy 433.42Mhz
Value (4 bits) (0x1 = my ; 0x2 = up ; 0x4 = down ; 0x8 = prog ; 0xf = gate)
Need rolling code
- Protocol_X10 - Static variable in class com.devmel.rf.Packet
-
Protocol X10
X10
Value (2 bits) (0 = on ; 1 = off ; 2 = bright ; 3 = dim)